Testing the Anemometer
Weather Monitor II Page 9
3. TESTING THE STATION
Before doing anything else, test the station in your living room or workshop. If
you have purchased the optional rain collector or additional sensors, now is
the time to assemble and test these using the appropriate manual. Consult the
Troubleshooting Guide on page 39, or the guides in the respective manuals, if
you experience any difficulty.
Note: You should test each external sensor without extension cables first, and then repeat the test with
extension cables. In this way, you can be reasonably sure whether any problems are the fault of the
extension cables or the external sensor itself.
TESTING THE ANEMOMETER
Before you install the anemometer, make sure that the wind speed and wind
direction sensors are functioning correctly.
1. Insert the cable plug at the end of the anemometer cable into the jack marked WIND
on the junction box.
2. Test your assembly by spinning the wind cups.
You should get a speed reading other than 0 on the compass rose in the console
display. If you do not, loosen the set screw and move the wind cups slightly up
or down on the shaft until you get a reading other than 0. Once you are getting a
reading, use the allen wrench provided to tighten the set screw on the side of the
wind cups. Do not over-tighten.
3. Turn the wind direction shaft (the larger of the two stainless steel shafts on the con-
trol head) with your fingers.
Check that the direction readings change on the compass rose in the console dis-
play.
TESTING THE EXTERNAL TEMPERATURE SENSOR
Be sure you get a reading from the external temperature sensor as well. Or, if
you have purchased the optional External Temperature/Humidity Sensor, be
sure to test both the temperature and the humidity readings at this time.
To Test the Temperature Sensor
1. Insert the cable plug at the end of the external temperature sensor into the jack
marked TEMP on the junction box.
2. Press TEMP.
A temperature reading and the words INSIDE and TEMPERATURE should
appear on the display.
3. Press TEMP again.
A temperature reading and the words OUTSIDE and TEMPERATURE should
appear on the display.