DAVIS Electronic Rain Counter Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Non DAVIS Electronic Rain Counter. DAVIS Electronic Rain Counter User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - C3 USER GUIDE

®C3 USER GUIDE®

Page 3 - 3. Installation 19

92. OverviewDescriptionThe C3 is a robust remote monitoring and control platform designed for deployment in rugged environments. The C3 platform consi

Page 4 - 4. Appendix 29

C3 User Guide101 - Battery status indicator2 - Radio status indicator3 - Power/user touch button4 - Output connector + indicator5 - Input connector +

Page 5 - A4. Physical dimensions 40

111 - Ventilation slots2 - Information label3 - DIN rail mount4 - DIN rail mount clip toggle5 - UHF BNC antenna connector6 - xG SMA antenna connector7

Page 6 - Electric pump control 77

C3 User Guide12&MFDUSJDBMTQFDJæDBUJPOTPower requirements• Connection via terminal block or 2.5 mm DC power connector• 60 V maximum on all power

Page 7 - 1. General Information

13Weight• .PEVMFLHEFQFOEBOUVQPOSBEJPDPOæHVSBUJPO• Packed: 2.1 kg maximumMounting• Standard 32 mm DIN rail (Figure 2-3)• Locking cl

Page 8

C3 User Guide14C3 Solar EnclosureComponents1 - Primary antenna whip2 - Mounting bracket3 - Bird deterrent4 - Primary antenna base5 - Secondary antenna

Page 9

15781 - Solar panel thumb bolt2 - Module mounting rail3 - Note clip4 - Door Latch5 - Padlock loop6 - Mounting thumb bolt7 - Breather/drain8 - Bottom e

Page 10 - C3 User Guide

C3 User Guide16&MFDUSJDBMTQFDJæDBUJPOTPower• Nominal 14 W, 18 V crystalline PV panel• Internally routed 2-core solar power cable with 4-way plu

Page 11 - 2. Overview

17Cable management• Single bottom entry M32 gland, suitable for electrical conduit up to 25 mm in diameter (Figure 4-8)• Two optional rear entry

Page 12 - Components

Published byObservant Pty LtdABN: 21 104 666 882ACN: 104 666 882Level 1106 Victoria StFitzroy Victoria 3065AustraliaP: 1300 224 688 (+61 3 8415 0288 i

Page 13 - C3-04078

C3 User Guide182ABTxRxRS232/SDIRS485INPUTOUTPUT4334INPUTOUTPUT2211POWER1ABRS48512C3Figure 5. C3 installed in Solar Enclosure

Page 14 - .FDIBOJDBMTQFDJæDBUJPOT

193. InstallationPreparationLocationCare must be taken when selecting a site for the installation of a C3. It should have a clear aspect (down to the

Page 15 - Product codes

C3 User Guide20antenna at a greater height above the ground if required. Greater pole diameters can be used if this is not a requirement.Pre-cablingIt

Page 16 - C3 Solar Enclosure

21• Un-fasten and tighten a hose-clamp around the mounting pole. • Mark the band approximately 15 – 20 mm past the worm-screw (Figure 6)• Cut three

Page 17

C3 User Guide22Cable routing option 1: Bottom entry• Remove the Solar Enclosure from packaging and assemble to mount via tabs, the enclosure need

Page 18

231 - Cable gland in place2 - Drill pilot mark3 - Pierce through cable gland123Figure 8. Optional rear entry cable glands3. Installation

Page 19

C3 User Guide2412Figure 9. Installing enclosure on mounting bracketPrimary antenna mounting• Remove primary antenna base from packaging, remove slott

Page 20

25123451 - Antenna base2 - Enclosure cross-section3 - Seal4 - Slotted nut (shoulder upward)5 - Antenna cableFigure 10. Primary antenna installationC3

Page 21 - 3. Installation

C3 User Guide26123ABFigure 11. C3 module mounting

Page 22 - Mounting bracket

27Figure 12. Bird deterrent mounting3. Installation

Page 23 - 2 - Hose-clamp (x3)

1Contents1. General Information 5About this guide 5Warranty 52. Overview 9Description 9C3 10Components 10&MFDUSJDBMTQFDJæDBUJPOT .FDIBOJD

Page 24

C3 User Guide28

Page 25 - 2 - Drill pilot mark

294. AppendixA1. Electrical connectionsEquipment and power connections to the C3 module are made via 4-way 3.81 mm pluggable screw terminal blocks, wi

Page 26 - Primary antenna mounting

C3 User Guide30Label Function1Input 1Ground2Input 2GroundTable 1. Input1/2 connections (Figure 1-5)INPUT21Label Function3Input 3Ground4Input 4GroundTa

Page 27 - C3 Module Installation

31Label Function3Output 3Ground4Output 4GroundTable 4. Output 3/4 connections (Figure 1-6)OUTPUT43RS232/SDI port• Nominal 12 V switched sensor power

Page 28 - Figure 11. C3 module mounting

C3 User Guide32RS485 ports (x2)• Nominal 12 V switched sensor power output (600 mA limit)• Standard 2-wire RS485 for multi-drop connections• Fault

Page 29

33Power connections (x3)• Operational up to 60 V• 40 W peak total power draw across all inputs• 100 – 500 mW typical draw depending upon radio tech

Page 30

C3 User Guide34RF antenna connections (x4)• $POOFDUJPOTBWBJMBCMFXJMMEFQFOEPODPOæHVSFESBEJPUFDIOPMPHZNJY• All connections are standard polari

Page 31 - 4. Appendix

35LED state Description4JOHMFHSFFOçBTIFWFSZTFDPOET• Battery healthy• No external power• Battery discharging%PVCMFHSFFOçBTIFWFSZTFDPOET• B

Page 32

C3 User Guide36LED state DescriptionSolid green Input activeFlashing green (2 Hz) Input pulsingOff No input active, or user mode inactiveTable 13. Inp

Page 33 - RS232/SDI port

37LED state Description.PNFOUBSZHSFFOçBTI Communications transmit.PNFOUBSZBNCFSçBTI Awaiting response.PNFOUBSZçBTIJOHSFE Communications response

Page 34 - RS485 ports (x2)

C3 User Guide2Location 19Mounting posts 19Pre-cabling 20Unpacking 20C3 Solar Enclosure installation 20Mounting bracket 20Primary antenna mounting

Page 35 - SIM card

C3 User Guide38 powered down until the button is pressed once again, or external power is presented• Note that activation of the button can be obs

Page 36 - A2. User interface reference

3940°30°50°Figure 13. Solar panel angle setting4. Appendix

Page 37 - LED state Description

C3 User Guide40A4. Physical dimensions®50 – 90 mm (1.5 – 3” nominal) pipe diameter110 mm74 mm~455 mm328 mmUp to 420 mmFigure 21. Solar enclosure mount

Page 38

4175mm164mm215mmC3POWER1ABRS485INPUT OUTPUT2AB TxRxINPUT RS232/SDIOUTPUT RS485221433411 2Figure 22. C3 dimensions 4. Appendix

Page 39 - Power/user touch button

C3 User Guide42A5. Device cabling guidelinesProtection• No cable (or part thereof) should be left exposed to the elements• The use of rigid electric

Page 40 - Pinhole reset button

43Connections• Observant devices (V1, M2, L1) come pre-terminated with a waterproof 4-way in-line connector. Tails and extensions for these

Page 41

C3 User Guide44Pulsed input• A pulsed switch or voltage output can be connected to a C3 input, for  FYBNQMFBXBUFSçPXNFUFS• The frequency of th

Page 42 - A4. Physical dimensions

4512 VDC240 VAC<600 mAOUTPUT21 Latch ReleaseOUTPUT21Figure 16. Control output examples4-20 mA analog input• Any loop powered 4 – 20

Page 43 - Figure 22. C3 dimensions

C3 User Guide46Voltage analog input• The C3 inputs can measure voltages up to 10 V• Higher voltage ranges can be measured by employing a divider res

Page 44 - A5. Device cabling guidelines

47PowerRS485+RS485-Ground12 VDC<600 mAPowerRS485+RS485-GroundPowerRS485+RS485-GroundDevice 1 Device 2 Device n1ABRS485Figure 19. RS485 wiringPowerR

Page 45 - 5 – 30 VDC

3A4. Physical dimensions 40A5. Device cabling guidelines 42Protection 42Distance 42Connections 43A6. Generic device wiring examples 43Switched inpu

Page 46 - Max 1 kHz

C3 User Guide48A7. Supported sensing and control devicesObservant V1 cameraDescriptionThe V1 is a low-power, ruggedised, colour still image camera. It

Page 47 - 4-20 mA analog input

49RedBlueYellowGreenABRS4851duleeowePOWER12121 - Male 4-way device connector (DTC)2 - Female 4-way device connectorFigure 22. V1 camera connection4. A

Page 48 - Serial devices

C3 User Guide50Figure 23. V1 mounting (rigid conduit)

Page 49 - Figure 21. SDI-12 wiring

51'JHVSF7NPVOUJOHçFYJCMFDPOEVJU4. Appendix

Page 50 - Observant V1 camera

C3 User Guide52Figure 25. V1 mounting (direct)

Page 51

53Observant M2 engine controllerDescriptionThe M2 is a fully featured engine monitoring and control interface. It communicates to the C3 via a 4-way c

Page 52

C3 User Guide54EMERGENCY STOPSTART/STOPM2TMCommsBAPWR INRS485PM hrottleSparewnOKActiv–RedBlueYellowGreenRedBlueYellowGreenABRS4851duleeowePOWER12121 -

Page 53

55Vaisala weather stationDescriptionThe Vaisala WXT520 is a multi-sensor weather station with no moving parts. Measurements of wind speed, direction,

Page 54

C3 User Guide564FOTPSDPOåHVSBUJPO• 5IF895NVTUCFDPOæHVSFEWJBUIF7BJTBMBDPOæHVSBUJPOUPPMUPXPSL correctly with the Observant system• 8

Page 55

57RedBlueYellowGreenABRS4851duleeowePOWER12211 - Male 4-way device connector (DTC)2 - Female 4-way device connectorFigure 27. Vaisala WXT520 electrica

Page 56

C3 User Guide4A8. Other typical installation examples 77Electric pump control 77Mechanical engine monitoring and shutdown 80Equipment shutdown and

Page 57 - Vaisala weather station

C3 User Guide58Senix ultrasonic level sensorDescriptionThe Senix ToughSonic TSPC ultrasonic level sensor can be used to measure water level in tanks,

Page 58

59BrownYellowGreyBlueABRS4851oeuwowyPOWER12Figure 28. Senix TSPC connection4. Appendix

Page 59

C3 User Guide60Linak Modbus enabled actuatorDescriptionThe Linak LA-35 and LA-36 series of linear actuators can be used to open, close or position irr

Page 60 - Senix ultrasonic level sensor

611 - Linak comms tail2 - Linak power tail3 - Fuse (10 A) 4 - Flexible conduit5 - C3-A power connector1ABRS485POWER2ABTxRxRS232/SDIRS48512NCBlackGreyB

Page 61

C3 User Guide62Mono SMCDescriptionThe Mono SMC is an electric motor controller used in Mono Sun-Ray SRX solar water pumping systems. When connected to

Page 62 - Linak Modbus enabled actuator

63ON/OFFSPEEDSTATUS LIGHTSFLASHINGOFFDELAYDELAYHIGHTEMPSOLAR MOTOR CONTROLLERSOLAR PUMPING SYSTEMHAZARDOUS VOLTAGE INSIDE NOUSER SERVICABLE PARTSWARRA

Page 63

C3 User Guide64Davis rain gaugeDescriptionThe Davis Rain Collector II is a typical example of a tipping bucket rain gauge with a 2-wire connection. Th

Page 64 - Mono SMC

65OUTPUT21INPUT21RedGreenFigure 31. Davis rain gauge electrical connection4. Appendix

Page 65 - device connector (MNK)

C3 User Guide66Pakton electric fence monitorDescriptionThe Pakton PTE0703 provides electrics fence voltage information over an RS232 serial link to th

Page 66 - Davis rain gauge

67Electric Fencing SecurityTxRxRS232/SDI2ABRS485RedYellowBlueGreenHigh voltage fence connections Figure 32. Pakton PTE0703 electrical connection4. App

Page 67

51. General InformationAbout this guideThis document provides information on the features, installation and typical usage of UIF$SFNPUFNPOJUPSJOH

Page 68 - Pakton electric fence monitor

C3 User Guide68.BDF9$JçPXNFUFSTDescription5IF.BDF9$JJTBEPQQMFSçPXNFUFSUIBUDBOCFDPOæHVSFEUPQSPWJEFJOTUBOUBOFPVTBOEUPUBMJTFEXBUFSçP

Page 69 - Electric Fencing Security

69Installation notes• The C3 is typically mounted separately from the Mace meter, but can exist on the same pole provided enough vertical room is

Page 70 - .BDF9$JçPXNFUFST

C3 User Guide70Sentek soil moisture probeDescriptionThe Sentek soil moisture probe measures soil electrical conductivity and moisture content. The pro

Page 71 - FLOSI CARD

71RedBluePurpleBlackABRS4851euuadepcPOWER12Figure 34. Sentek probe electrical connection4. Appendix

Page 72 - Sentek soil moisture probe

C3 User Guide72Aquacheck soil moisture probeDescriptionThe Aquacheck soil moisture probe measures soil temperature and moisture content. The probes ar

Page 73

73BrownBlackBlueGrn/YellowABRS4851neoPOWER12Figure 35. Aquacheck probe electrical connection4. Appendix

Page 74 - Aquacheck soil moisture probe

C3 User Guide74ADAM 4000 series IO modulesDescriptionObservant supports a range of ADAM 4000 IO expansion modules for cases where more digital inputs/

Page 75

75Product codes• DTC: 6 m 4-way device cable (required for connection to C3)• DTE: 10 m 4-way device cable extension• DTB: 60 cm 4-way device cable

Page 76 - ADAM 4000 series IO modules

C3 User Guide76Other supported devicesObservant supports a further and continuously expanding range of serially connected devices. Please refer to the

Page 77 - (R) Data

77A8. Other typical installation examplesElectric pump controlDescriptionThe digital outputs of the C3 can be used to control contactors associated wi

Page 78 - Other supported devices

C3 User Guide6required by Observant to evaluate and process any warranty claim.3. In order to obtain the above warranty service you will be asked to

Page 79 - Electric pump control

C3 User Guide78OUTPUT21INPUT21A1A212A1A212A1A212A1A212STARTSTOPExisting12341 - Existing contactor2 - Start button3 - Stop button4 - 12 VDC/240 VAC rel

Page 80

79OUTPUT21INPUT21A1A212A1A212Existing132RUNOFFAUTO1 - Existing contactor2 - Run switch3 - 12 VDC/240 VACFigure 38. Single input electric pump control4

Page 81 - 3 - 12 VDC/240 VAC

C3 User Guide80Mechanical engine monitoring and shutdownDescriptionA combination of a C3 digital input and output can provide a simple method to add a

Page 82

81OUTPUT21INPUT21GroundProtected ignitionFuel solenoid hold-in121 - Generic 12 VDC NC automotive relay2 - Engine with existing shutdown protectionFigu

Page 83 - Fuel solenoid hold-in

C3 User Guide82Equipment shutdown and alarm triggersDescriptionThe C3 inputs can be used to sense conditions where equipment should be turn on/off, or

Page 84

83OUTPUT21INPUT21NC or NOCommonFigure 40. Pressure switch electrical connectionOUTPUT21INPUT21NC or NOCommonFigure 41. Flow switch electrical connecti

Page 85

C3 User Guide841 - Dry contact hall/inductive trigger4IBGUçZXIFFMXJUIGFSSPVTUSJHHFSOUTPUT21INPUT21NC or NOCommon12Figure 42. Shaft speed senso

Page 86

85OUTPUT21INPUT21NC or NOCommonA1A212A1A212To mains or motor supplyFigure 44. Mains power supply monitoring electrical connection4. Appendix

Page 87 - To mains or motor supply

C3 User Guide86RevisionsOBS-USR-M001-C3 User GuideR1: Initial release September 2012 (AJK)R2: February 2013 (AJK)• Added IP ratings, design life and

Page 88 - Revisions

874. Appendix

Page 89

7SUCH LOSS OR DAMAGE IS DIRECT, INDIRECT, CONSEQUENTIAL, SPECIAL, PUNITIVE OR EXEMPLARY (INCLUDING WITHOUT LIMITATION, LOSS OR DAMAGE, ANY LOSS OF PRO

Page 90

Designed and made in Australiaobservant.com.au

Commentaires sur ces manuels

Pas de commentaire