X-MDA-1™ User Manual Installation and X-320M™ Setup
2.3 X-320M Sensor Configuration
Please refer the X-320
TM
and X-320M
TM
manuals for set up of the network parameters, email, NTP,
logging, and other general settings. The following instructions are for the use and configuration of the
Davis Sensors only.
The following instructions presume that the user is familiar with the X-320 interface or can refer to the
product user manual when necessary. Specific instructions, such as submitting changes or selecting
tabs, are omitted; only the sensor configuration settings are given.
2.4 I/O
I/O 1 (Wind Speed)
Mode: Input
Pull-Up/Down Select: Pull-Up Resistor
Counter Options: Increment when input on
Debounce Time (ms): 1
I/O 2 (Rain Bucket)
Mode: Input
Pull-Up/Down Select: Pull-Up Resistor
Counter Options: Increment when input off
2.5 Wind Speed
Sensor Connection: Rate 1
Slope: 2.25
Offset: 0.00
Avg. Period: 2 min (This is a typical setting and may be adjusted by the user.)
Units: mph
2.6 Wind Direction
Sensor Connection: Analog 2
Slope: 72
Offset: 0
Avg. Period: 2 min
Units: Degrees