The Alarm Output Module (AOM) enables you to use weather station alarms
or commands from your computer to automatically start or stop external
devices such as indicator lights, audio alarms, sprinkler controllers, relays, or
other low-voltage AC or DC loads. The AOM works with the GroWeather™,
Energy EnviroMonitor™, or the Heath EnviroMonitor™. The
GroWeatherLink
®
and Energy WeatherLink
®
also allow you to control two
alarm outputs manually (by turning them on or off from the software), though
the software is not required for basic operation.
CAUTION:
WHILE WE HAVE MADE EVERY EFFORT TO INSURE THAT THE ALARM OUTPUT MODULE
WILL WORK RELIABLY, YOU SHOULDNOT USE IT IN SITUATIONS INVOLVING POTENTIAL
PROPERTY LOSS OR HAZARDS TO HEALTH OR SAFETY OF PEOPLE OR LIVESTOCK. DAVIS
INSTRUMENTS CANNOT BE HELD LIABLE FOR ANY FAILURE OF THE ALARM OUTPUT
MODULE.
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Product #7736

Product #7736 A LARM O UTPUT M ODULE The Alarm Output Module (AOM) enables you to use weather station alarms or commands from your computer to auto

Page 2 - ATERIALS

Page 10 Alarm Output Module ✦ Selecting between normally-open and normally closed operation If you select normally-open operation, each of the four a

Page 3 - NSTALLATIONS

Operation of the Alarm Output Module Page 11Connecting the OutputsThe output devices are photo-coupled MOS transistors. They provide floating “contacts

Page 4

Page 12 Alarm Output ModuleAOM Connections for Radio Power-Conserving OptionsFor power conservation when using a solar-battery-powered wireless Weathe

Page 5 - PERATION

Operation of the Alarm Output Module Page 13Powering the AOMYou may use a separate AC-power adapter for the AOM and the console, or you may use the po

Page 6 - SSIGNMENTS

Page 14 Alarm Output ModuleMounting the AOMYou may mount the AOM against a wall or other vertical surface or you may simply set it down on a horizonta

Page 7

Operation of the Alarm Output Module Page 15

Page 8

Product Numbers: 7736Davis Instruments’ Part Number: 7395-085Alarm Output Module ManualRev. B Manual (7/7/99)This product complies with the essential

Page 9 - ONNECTING

Page 2 Alarm Output Module C OMPONENTS The AOM includes the following components. Please make sure you have all listed components before continuing.

Page 10 - IRES NOT SHOWN)

Typical AOM Installations Page 3 T YPICAL AOM I NSTALLATIONS The AOM may be connected to either the sensor interface module or to the Interface Cabl

Page 11 - SECURING WIRES

Page 4 Alarm Output Module O PENING AND C LOSING THE A LARM O UTPUT M ODULE Remove the cover by pushing down on the tabs at the top until you

Page 12

Alarm Output Module Operation Page 5 A LARM O UTPUT M ODULE O PERATION The section below provides technical information on the operation of the Al

Page 13 - Powering the AOM

Page 6 Alarm Output Module Available Outputs The AOM provides four output contacts which may be selected from the condi-tions listed below. Each outp

Page 14 - TTACHING ADHESIVE PADS

Alarm Output Module Operation Page 7 Basic AOM Information The AOM outputs are updated by the console at intervals of approximately 3 seconds. The da

Page 15

Page 8 Alarm Output Module ✦ Latch Circuit Outputs (L1 and L2) and Red LED Indicators The AOM includes two latch circuits; each has one output contac

Page 16

Operation of the Alarm Output Module Page 9 ✦ AOM Cover Label The label on the cover of the AOM provides spaces in which you may write the name of th

Commentaires sur ces manuels

Pas de commentaire